This website is provided for discussion purposes only. The attached screenshot shows the additional information when the mouse is hovered over the key icon. You can also use the below options to login. Provide the permalink of a topic that is related to this topic. All content copyright SafeNet, Inc. If it has expired, please contact your sales representative at or sales eng-software. V2C License File If you are continuing to have problems, please contact technical support and supply them with:
Equipment: Sentinel License Manager. Gemalto recommends users who have Sentinel LDK run-time environment (RTE) Version 2.10.
Uploader: | Majinn |
Date Added: | 22 March 2010 |
File Size: | 22.35 Mb |
Operating Systems: | Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X |
Downloads: | 81773 |
Price: | Free* [*Free Regsitration Required] |
However, battery life can be increased to at least ten years if the key remains connected to an operating computer. Leave a comment on schurilov’s reply.
New to this Safenet inc hasp key When your hardware key is plugged into your computer, a light should illuminate. How to Apply a.
SafeNet USB Driver for Windows 10 bit – Gemalto Sentinel Customer Discussions
Publish Back to edit Cancel. I used it on Windows 7 bit with success and now I would like to use it on Windows 10 bit.
Plug it back in and make sure a balloon tooltip pops up in the lower-right-hand corner of the safenet inc hasp key indicating that your system recognizes your hardware safenef.
Sentinel Admin Control Center page opens with an empty table.
Support for HASP
However, the keys seems unable to communicate with the license manager since they are not appearing on the portal. Safenet inc hasp key were no problems in the upgrading process. Type the characters you see in the picture below. Its detected correctly on my side.
Leave a comment on Ashish’s reply. Provide the permalink of a topic that is related to this topic. Open Admin Control Center page and place safenet inc hasp key pointer where the key is shown. Hence, this appears to be a environment specific concern.
Ensure that your license is still active by checking your deactivation date. Any act or omission by a reader of this site is at the sole risk of the reader, and SafeNet, Inc. Please check if the haep persists on safenet inc hasp key side with multiple keys and multiple windows Machines.
All content copyright SafeNet, Inc. Each Attachment size should not exceed 5.
Max no of attachments: Discussions Questions Ideas Problems. Thanks for your feedback Ashish. Engineered Software Knowledge Base.
USB Key with the previous mention version. You can also use the below options to login.
USB Universal Serial Bus – SafeNet Inc. – SafeNet Inc. Sentinel HASP Key Drivers Download
Please check and share the following details- 1. Open CMD with admin rights and execute this command: Click on Join Now to Sign Up. The issue at your end would need detailed investigation. Can hhasp tell me which driver can be used for the usb dongle in Win10 bit? I need recommendation of the correct driver for my Safenet inc hasp key usb safenet inc hasp key for a program from Unblock any blocked USB ports.
If it hawp expired, please contact your sales representative at or sales eng-software. Disconnect the key from Windows machine and uninstall the drivers using command line installer haspdinst.
Related Drivers
CVSS v3 9.9
ATTENTION: Remotely exploitable/low skill level to exploit.
Vendor: Gemalto
Equipment: Sentinel License Manager
Vulnerability: Null Pointer Dereference, Buffer Overflows, Improper Access Control
AFFECTED PRODUCTS
The following Sentinel License Manger services are affected:
- All HASP SRM, Sentinel HASP, and Sentinel LDK products prior to Sentinel LDK RTE 7.55
IMPACT
Successful exploitation of these vulnerabilities could lead to remote code execution or cause a denial-of-service condition, rendering the Sentinel LDK License Manager service unavailable.
MITIGATION
Gemalto recommends users who have Sentinel LDK run-time environment (RTE) Version 2.10 through Version 7.54 update to Sentinel LDK RTE component Version 7.6, or the latest version. The update was available as of July 2017 and can be found at the following location:
For more information about these vulnerabilities, users can contact customer support at:
Or visit the vendor’s customer portal at:
NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:
- Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
- Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
In addition, NCCIC recommends that users take the following measures to protect themselves from social engineering attacks:
- Do not click web links or open unsolicited attachments in email messages.
- Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
- Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
No known public exploits specifically target these vulnerabilities.
VULNERABILITY OVERVIEW
Language packs (zip files) with invalid HTML files lead to NULL pointer dereferences, which could be exploited by an attacker leveraging malicious HTML files. This could lead to a denial-of-service condition.
CVE-2017-11498 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
Language packs containing file names longer than 1,024 characters and malformed ASN.1 streams in input files can lead to a stack-based buffer overflow. This may allow remote code execution.
CVE-2017-11497 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Malformed ASN.1 streams in V2C and similar input files can be used to generate stack-based buffer overflows. This could allow remote code execution.
CVE-2017-11496 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
XML payload with more than supported number of elements leads to buffer overflow of a variable in stack. This vulnerability can be exploited for denial of service.
CVE-2017-12818 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
XML payload with more than supported number of elements leads to buffer overflow of a variable in stack. This vulnerability can be exploited for denial of service or arbitrary code execution.
CVE-2017-12821 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Malformed HTTP request body in Admin APIs can be used to generate heap buffer overflows. This vulnerability can be exploited for denial of service.
CVE-2017-12820 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
License manager web interface is enabled as a default configuration, and even if disabled, it can be re-enabled remotely. This vulnerability can be exploited to perform above mentioned attacks remotely.
CVE-2017-12822 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L).
RESEARCHER
![Hasp Hasp](https://knowledge.faro.com/@api/deki/files/10433/kA270000000CaSUCA0_en_US_1_9.png?revision=1)
Kaspersky Labs ICS-CERT reported these vulnerabilities to Gemalto CERT and NCCIC.
BACKGROUND
Critical Infrastructure Sectors: Communications, Financial Services, Government Facilities, Healthcare and Public Health, Information Technology
Countries/Areas Deployed: Worldwide
![Sentinel Sentinel](/uploads/1/2/5/5/125518305/935809290.png)
Company Headquarters Location: Netherlands
Contact Information
For any questions related to this report, please contact the NCCIC at:
Email: [email protected]
Toll Free: 1-888-282-0870
Email: [email protected]
Toll Free: 1-888-282-0870
For industrial control systems cybersecurity information: http://ics-cert.us-cert.gov
or incident reporting: https://ics-cert.us-cert.gov/Report-Incident?
or incident reporting: https://ics-cert.us-cert.gov/Report-Incident?
The NCCIC continuously strives to improve its products and services. You can help by choosing one of the links below to provide feedback about this product.
This product is provided subject to this Notification and this Privacy & Use policy.